PHILIPPINE ELECTRICAL CODE REVIEWER
The P.E.C. 2009 consists of two (2) parts:
1. Practical Safeguarding
Mandatory Rules, Permissive Rules, & Explanatory Material:
Coverage or Scope of PEC 2009
Reconnection of Disconnected Service
ELECTRICAL PLANS AND SPECIFICATIONS Drawing Sheet Sizes
c) General Notes and/or Specifications
d) Electrical Layout 1. Plan for Power
2. Plan for Lighting and Receptacle Outlets
Title Block or Nameplate of Plans and Drawing
Other Details for Electrical Plans
Substation Plans and Specifications Indoor Substation
The Criteria for Examination of Electrical Inspection: Warning Sign for Voltages Exceeding 600 Volts
Measurements for Access to Manholes
Ground Fault Circuit Interrupter Protection
BRANCH-CIRCUIT RATINGS Conductors - Minimum Ampacity and Size
Lighting Outlets Required
Feeders with Common Neutral
BRANCH CIRCUIT, FEEDER, AND SERVICE CALCULATIONS Calculations
OUTSIDE BRANCH CIRCUITS AND FEEDERS Conductor Size and Supports
Buildings or Structures requiring Additional Feeders/Service Entrance:
Conductors Considered Outside the Building
Clearance of Service Lateral:
Equipments Connected to the Supply Side Service Disconnect:
Services Exceeding Six Hundred Volts, Nominal
Maximum Number of Disconnects
Rating of Service Disconnecting Means:
Fuses or Circuit Breakers in Parallel
Change in Size of Grounded Conductor
Locations in or in Premises
Overcurrent Protection over 600V, Nominal
General Requirements for Grounding and Bonding:
Connection of Grounding and Bonding Equipment
Circuits Not To Be Grounded
Main Bonding Jumper and System Bonding Jumper
Grounding Electrodes (Electrodes Permitted for Grounding)
Equipment Grounding and Equipment Grounding Conductors
Identification of Equipment Grounding Conductors
Identification of Wiring Device Terminals:
Size of Direct-Current Grounding Electrode Conductor:
Surge Arrester Selection:
TRANSIENT VOLTAGE SURGE SUPPRESSOR (TVSS)
PROTECTION AGAINST LIGHTING
Protection for Ordinary Buildings
WIRING METHODS Conductors of Different Systems
Protection against Physical Damage
Mechanical and Electrical Continuity - Conductors
Length of Free Conductors at Outlets, Junctions, and Switch Points
Wiring in Ducts, Plenums, and Other Air-Handling Spaces
Panels Designed to Allow Access
Requirements for Over Six hundred Volts, Nominal
CONDUCTORS FOR GENERAL WIRING Stranded Conductors
CABINETS, CUTOUT BOXES, AND METER SOCKET ENCLOSURES
Enclosures for Switches or Overcurrent Devices
Construction Specifications (Cabinets, Cutout Boxes, and Meter Socket Enclosures)
OUTLET, DEVICE, PULL, AND JUNCTION BOXES; CONDUIT BODIES; FITTINGS; AND HANDHOLE ENCLOSURES Round Boxes
Pull and Junction Boxes and Conduit Bodies
INTEGRATED GAS SPACER CABLE: TYPE IGS
Uses Not Permitted FLAT CABLE ASSEMBLIES: TYPE FC
FLAT CONDUCTOR CABLE: TYPE FCC
MEDIUM VOLTAGE CABLE: TYPE MV
SERVICE-ENTRANCE CABLE: TYPES SE AND USE
MINERAL-INSULATED, METAL-SHEATHED CABLE: TYPE MI
POWER AND CONTROL TRAY CABLE: TYPE TC
NONMETALLIC-SHEATHED CABLE: TYPES NM, NMC, AND NMS
UNDERGROUND FEEDER AND BRANCH-CIRCUIT CABLE: TYPE UF
INTERMEDIATE METAL CONDUIT: TYPE IMC
RIGID METAL CONDUIT: TYPE RMC
RIGID NONMETALLIC CONDUIT: TYPE RNC
FLEXIBLE METAL CONDUIT: TYPE FMC
LIQUIDTIGHT FLEXIBLE METAL CONDUIT: TYPE LFMC
HIGH DENSITY POLYETHYLENE CONDUIT: TYPE HDPE CONDUIT
NONMETALLIC UNDERGROUND CONDUIT WITH CONDUCTORS: TYPE NUCC
LIQUIDTIGHT FLEXIBLE NONMETALLIC CONDUIT: TYPE LFNC
ELECTRICAL METALLIC TUBING: TYPE EMT
FLEXIBLE METALLIC TUBING: TYPE FMT
ELECTRICAL NONMETALLIC TUBING: TYPE ENT
CELLULAR FLOOR RACEWAYS (CONCRETE AND METAL)
CONCEALED KNOB-AND-TUBE-WIRING
OTHER APPROVED WIRING METHODS BY P.E.C. STRUT-TYPE CHANNEL RACEWAY
SURFACE RACEWAYS (METAL AND NON METAL)
MESSENGER SUPPORTED WIRING
CHAPTER 4 - EQUIPMENT FOR GENERAL USE
RECEPTACLES, CORD CONNECTORS, AND ATTACHMENT PLUGS (CAPS) Rating
SWITCHBOARDS AND PANELBOARDS
APPLIANCES Provisions for appliances (In General):
MOTORS, MOTOR CIRCUITS, AND CONTROLLERS
Marking on Motors and Multi-motor Equipment
Single Motor (Selection of Branch-Circuit Conductors)
Rating for Continuous-Duty Motors
c) Selection of Overload Relay
Table 4.30.14.2 Full-Load Currents in Amperes, Single-Phase Alternating-Current Motors
Table 4.30.14.4 Full-Load Current, Three-Phase Alternating-Current Motors
AIR-CONDITIONING AND REFRIGERATING EQUIPMENT
Specific Provisions Applicable to Different Types of Transformers a) Dry-Type Transformers Installed Indoors
CAPACITORS Enclosing and Guarding
600 Volts, Nominal, Under
RESISTORS AND REACTORS Space Separation
CHAPTER 5 - SPECIAL OCCUPANCIES
Reference Standards of Hazardous Locations
HAZARDOUS LOCATIONS Classifications
MATERIAL GROUPS MESG - Maximum Experimental Safe Gap MIC - Minimum Igniting Current Ratio Classifications:
CLASS II GROUP CLASSIFICATIONS
CLASS I, ZONE 0, 1, AND 2 LOCATIONS Types of Protection:
Classification of Locations:
ZONE 20, 21, AND 22 LOCATIONS
Task Illumination and Selected Receptacles for Critical Branch
THEATERS, AUDIENCE AREAS OF MOTION PICTURE AND TELEVISION STUDIOS, PERFORMANCE AREAS, AND SIMILAR LOCATIONS
CARNIVALS, CIRCUSES, FAIRS, AND SIMILAR EVENTS Overhead Conductor Clearances
Portable Distribution or Termination Box
MOTION PICURE AND TELEVISION STUDIOS AND SIMILAR LOCATIONS
MOTION PICTURE PROJECTION ROOMS
MOBILE HOMES, MANUFACTURED HOMES, AND MOBILE PARKS
Mobile Homes Not Intended as Dwelling Unit
RECREATIONAL VEHICLES AND RECREATIONAL VEHICLE PARKS
Means for Connecting to Power Supply
CRANES AND HOISTS Contact Conductors
ELEVATORS SWIMMING POOLS, FOUNTAINS, AND SIMILAR LOCATIONS
Cord-and-Plug Connected Equipment
Underground Wiring Locations
Junction Boxes and other Enclosures
SOLAR PHOTOVOLTAIC SYSTEMS
Ground-Fault Protection of Equipment
RADIO AND TELEVISION EQUIPMENT Clearances - Receiving Stations
Standard Rating of Busways or Busducts (Amperes) Standard Sizes of Pull Boxes and Junction Boxes Trade Name Wires and Conduits