Fecal Contamination of Drinking-Water in Low- and Middle-Income Countries: A Systematic Review and Meta-Analysis
Summary
Background Access to safe drinking-water is a fundamental requirement for good health and is also a human right. Global access to safe drinking-water is monitored by WHO and UNICEF using as an indicator “use of an improved source,” which does not account for water quality measurements. Our objectives were to determine whether water from “improved” sources is less likely to contain fecal contamination than “unimproved” sources and to assess the extent to which contamination varies by source type and setting. Methods and Findings Studies in Chinese, English, French, Portuguese, and Spanish were identified from online databases, including PubMed and Web of Science, and grey literature. Studies in low- and middle-income countries published between 1990 and August 2013 that assessed drinking-water for the presence of Escherichia coli or thermotolerant coliforms (TTC) were included provided they associated results with a particular source type. In total 319 studies were included, reporting on 96,737 water samples. The odds of contamination within a given study were considerably lower for “improved” sources than “unimproved” sources (odds ratio [OR] = 0.15 [0.10–0.21], I2 = 80.3% [72.9–85.6]). However over a quarter of samples from improved sources contained fecal contamination in 38% of 191 studies. Water sources in low-income countries (OR = 2.37 [1.52–3.71]; p<0.001) and rural areas (OR = 2.37 [1.47–3.81] p<0.001) were more likely to be contaminated. Studies rarely reported stored water quality or sanitary risks and few achieved robust random selection. Safety may be overestimated due to infrequent water sampling and deterioration in quality prior to consumption. Conclusion Access to an “improved source” provides a measure of sanitary protection but does not ensure water is free of fecal contamination nor is it consistent between source types or settings. International estimates therefore greatly overstate use of safe drinking-water and do not fully reflect disparities in access. An enhanced monitoring strategy would combine indicators of sanitary protection with measures of water quality.
Key Points
- 1Improved water sources still show significant fecal contamination
- 2Rural and low-income water sources have higher contamination rates
- 3Current monitoring metrics may overstate safety of drinking-water
- 4More rigorous water quality assessments are needed for true safety evaluation
Related articles
Evaluating large language models for clinical note processing: local fine-tuning and internal-external validation using electronic health records from South Asia
This research paper evaluates the effectiveness of large language models for processing clinical notes from electronic health records in South Asia, focusing on local fine-tuning and validation. It discusses the potential application of LLMs in clinical settings, particularly in resource-limited environments.
Cardiac Cycle & Physiology: Understanding Cardiac Function
This document provides a detailed overview of cardiac physiology, including the cardiac cycle, blood flow processes, and the cardiac conduction system. It aims to inform readers about the mechanics of the heart and its role in circulation.
Cardiac Cycle & Physiology
This document provides a comprehensive overview of cardiac cycle phases, blood flow through the heart, and the electrophysiology of cardiac conduction. It details the processes of deoxygenation and oxygenation of blood and the physiological aspects of cardiac output and common cardiovascular assessment findings.
The Dual Pillars of Clinical and Community Care
This document provides an in-depth examination of nutritional assessment and surveillance in clinical and community settings, offering guidelines on measuring malnutrition indicators and the importance of dietary interventions.
Cather Simpson Lecture Research Brief Inaugural David Breen
Cather Simpson Lecture Research Brief Inaugural David Breen Lecture | 14 October 2026 | 12 pm to 1 pm | AM103 The "Nespresso" of Diagnostics: Centrifugal Microfluidics for Point-of-Care Diagnostics; “Can we